FireNET™ Plus 1127 - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

DESCRIPTION 

 

The FireNET™ Plus 1127 series control panel is an analog addressable fire alarm panel with build options containing 1 or 2 SLC loops, a Digital Alarm Communicator/ Transmitter (DACT), and an RS-485 bus for network communication. Each SLC loop supports 127 devices of any combination (sensors or modules), and 127 analog sounder bases, for a possible total of 254 points per loop. Communication between devices is accomplished by use of standard cable (shielded or twisted pair is not required). Each panel includes a 4-amp power supply and has 2 onboard NAC circuits. The RS-485 bus provides communication to the panel network while another RS-485 bus provides communication for peripheral devices. The RS-232 interface allows the convenience of programming via a PC. The system will support a variety of Hochiki devices; photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity modes. Additional devices include contact monitors, relay controllers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone monitoring module. The Loop Explorer Windows® Software interface provides the installer with fingertip access to installation programming and diagnostic tools. An Auto Learn feature offers the convenience for quick start applications. Add to this a reputation for high quality and dedicated service which makes this an exceptional product both in performance and value.

 

 

Analog design using Hochiki’s advanced DCP

 

 

  • Protocol for fast communication
  • Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop
  • Uses standard wire, no-shielded or twisted pair required on SLC loops
  • Integrated digital alarm communicator (DACT) with Contact ID and SIA reporting formats
  • Programmable sensitivity levels by device
  • Alarm Verification feature
  • Automatic daily calibration & drift compensation routine
  • Large 8-line x 40-character LCD display (320 char.)
  • 1 or 2 loop (option)
  • RS-485 bus for panel network (option)
  • Built-in RS-232 interface for programming via a PC
  • 3 on board programmable Form C relays rated at 1 amp at 30VDC
  •  2 auxiliary power outputs, each rated 360mA at 24 VDC
  • Loop Explorer Windows® configuration utility
  • Auto-learn feature
  • 500 network wide software zones
  • Network Capability of up to 64 panels (option)
  • Built in help and alarm information screens
  • 2 on-board Class B (style Y) NAC circuits rated at 2.3 amps each (Special Application) and 1.6 amps each (Regulated continuous)
  • Gentex, System Sensor, Wheelock, and Amseco NAC sync protocol built-in
  • Automatic day/night sensitivity modes
  • Fire Drill test function
  • Walk Test function
  • Powerful & versatile Cause & Effect wizard including:
  • *Cause & Effect action
  • *Disable function configuration
  • *Test mode configuration
  • Seismic Certified